Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13600862

- Product Categories
- Friendly Links
Information Name: | Electronic rangefinder rangefinder _ _ Branch of the Instrument |
Published: | 2015-03-16 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | Laser vertical collimator 1. placement, alignment, leveling the tripod placed on the station, the instrument installed in the base of the tripod center hole to force the locking base clamp knob, the instrument stable. Height adjustable tripod laser rangefinder principle, the telescope eyepiece roughly human eye contour. Open to point the laser switch, adjust the hand wheel on the spot focusing the laser is focused on the measurement site. Adjustable tripod, so the bubble is centered round blisters. Turn the instrument alidade so vial with screw connection between any two feet parallel, the same amount in the opposite direction rotating two leveling screws so that the bubble is centered. The instrument alidade rotated 90 ?, swirling spiral third leg, the bubble is centered. Using the above method repeatedly adjusted until the instrument is rotated to any position of the ultrasonic range finder, bubble maximum deviation value does not exceed a quarter of the grid value. The instrument alidade rotates 180? Inspection of the circumstances, if any deviation from the range finder, infrared range finder loosen center screw, the head of the entire instrument rack pan, until the laser spot and precise alignment of the station. Turn the alidade, confirm that the instrument is rotated to any position, long level is centered, if deviation, repeat the above steps. Confirmation, and after leveling is completed, will point the laser turned off to save electricity. 2. Place the grid laser sighting target at the target. Turn the telescope eyepiece reticle crosshairs makes clear, then turn the focusing knob in the laser target reticle clear imaging, and try to eliminate parallax, that is, when the observer moves slightly sight, there can be between the reticle and the target significantly offset. Otherwise, you should continue to ignore the above steps until the poor. 3. A. upward vertical collimator optics vertical quasi If the instrument has been calibrated, when the instrument is leveled, the collimation axis coaxial with the vertical axis error ≤5 °, can be used as vertical alignment, a prospective observational ensure vertical accuracy. However, in order to improve the vertical quasi-precision instrument should be rotated 180 ?, alidade get a second observation through a telescope, whichever number (midpoint) of the measured values. B. laser vertical quasi-direct laser rangefinder to measure the distance: Press the first under the laser (note not facing the eye), targeting and then click to complete the distance measurements. Indirect measurement of distances: can indirectly measure the height of the front wall of the Pythagorean theorem. Measured area / volume: Use the space calculation function can easily calculate the area and volume of space. Splash measure: Thanks to IP54 protection grade design that allows you to operate freely in the construction site in a variety of harsh environments. Distance measuring the maximum distance Prism 600m (good weather) 5.0km figures show the largest single prism: 99999999.999 Minimum 1mm precision prism 2 + 2 ppm Prism 3 + 2 ppm measurement time precision measuring 0.8 seconds, 0.5 seconds average number of measurements to track can be selected 2 to 5 times the average of the input parameters of meteorological correction automatically correct refraction and earth curvature correction automatically correct input parameters Prism constant correction automatically correct the input parameters Angle measurement Absolute encoder 79mm diameter Minimum reading 1 "/ 5" may sorting accuracy 2 "level of detection methods offer: the vertical disc diameter: diameter Telescope As imaging Tube Length 154mm Effective aperture telephoto lens: 45mm, distance: 50mm Magnification 30 × FOV 1 ° 30 'Minimum focusing distance 1m resolution 3 "Automatic vertical compensation system biaxial liquid Optical electronic compensator working range ± 3 'accuracy of a" spirit level vial 30 "/ 2mm circular level 8' / 2mm Optical Plummet Image Erect enlarge 3 × magnification Focus range 0.5m ~ ∞ 5 ° field of view some types of double-sided display, numeric key + letter keys onboard battery power rechargeable Ni - MH battery Voltage DC 6V 8 hours continuous working time matching function measured Prism from the laser spot next to an SD card stores the size and weight Dimensions 200mm × 170mm × 350mm Weight 5.5㎏ electronic rangefinder rangefinder _ _ Jinke instrumentation provided by Qingdao Branch of the Instrument Co., Ltd. Qingdao Branch of the Instrument Co., Ltd. (www.qdjk17.com) strong, credible, in Qingdao, Shandong analytical instruments industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead the Branch of the Instrument and you hand in hand into the brilliant, for a better future! |
Admin>>>
You are the 23369 visitor
Copyright © GuangDong ICP No. 10089450, Instrument Co., Ltd. Qingdao Branch All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 23369 visitor
Copyright © GuangDong ICP No. 10089450, Instrument Co., Ltd. Qingdao Branch All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility